Peak Power and Cooling Energy Savings of Shade Trees
Reference Type
Journal, Research (Article)
"In the summer of 1992, we monitored peak power and cooling energy savings from shade trees in two houses in Sacramento, CA. The collected data include air-conditioning electricity use, indoor and outdoor dry bulb temperatures and humidities, roof and ceiling surface temperatures, inside and outside wall temperatures, insolation, and wind speed and direction. Shade trees at the two monitred houses yielded seasonal cooling energy savings of 30%, corresponding to an average daily savings of 3.6 and 4.8 kWh/d. Peak demand savings for the same houses were 0.6 and 0.8 kW (about 27% savings in one house and 42% in the other). The monitored houses were modeled with the DOE-2.1E simulation program. The simulation results underestimated the cooling energy savings and peak power reduction bas as much as twofold."Journal, Research (Article)
Authors
H. Akbari, D.M. Kurn, S.E. Bretz, J.W. Hanford
H. Akbari, D.M. Kurn, S.E. Bretz, J.W. Hanford
Date Published
1997
1997
Journal/Conference
Energy and Buildings
Energy and Buildings
Publisher
Elsevier Sequoia S.A
Elsevier Sequoia S.A
Publisher Location
Lausanne (CHE)
Lausanne (CHE)
ISBN/ISSN
0378-7788
0378-7788
Volume
25
25
Number
2
2
Attachments and Links
Sub-Topics
Economics/Cost-Benefit Analysis, Energy
Economics/Cost-Benefit Analysis, Energy
State(s)/Region(s)
California
California
Keywords
Cooling, Energy savings, Shade
Cooling, Energy savings, Shade
Hits
Total: 1607
Last 30 Days: 76
Click to open, view, print, and/or save this article as a PDF file